Retaining Wall Designer IS 456:2000 · IS 1893

Edit inputs - Cantilever Retaining Wall

Enter the geometry, soil, loads and materials. Units are shown with each field. The preview updates as you type.

Back to report

Project

Identification printed on the report and drawings.

Wall geometry

Heights are measured from the finished ground in front of the wall.

Top of wall = top of backfill
Foundation depth
Face of the stem that is inclined
Ignored for an L-shaped wall
For levels on the drawings
For the bar bending schedule and quantities

Shear key

Increases the sliding resistance by passive pressure in front of the key.

Soil, backfill and water

0 = level backfill; must be less than φ
e.g. 10 kPa traffic / construction
Fraction of the passive force relied upon

Seismic (IS 1893)

Mononobe-Okabe earth pressure; dynamic increment at mid-height.

Z/2 · I/R · Sa/g
2/3 usually

Safety and load factors

IS 456 cl 20 and Table 18.

0.9 Mr / Mo ≥ 1.4 (cl 20.1)
≥ 1.4 (cl 20.2)
1.5 (DL + LL)
1.2 (DL + LL + EL)

Materials and detailing

HYSD bars to IS 1786
IS 456 Table 16
≥ 50 mm for footings (cl 26.4.2.2)
Diameters the design may choose from
Code limit 3d or 300 mm also applies
Code limit 5d or 450 mm also applies