Reinforcement detailing - Cantilever Retaining Wall
Change the bar diameter or spacing of any item. Every change is checked against IS 456 at once and the
section preview updates; "Design" shows the bars of the automatic design. Click a row for the detailed checks.
Steel (10.0 m of wall)-
Automatic design-
Difference-
Steel per m³-
User-defined items-
Items failing-
| Mark | Member / face | D (mm) | As,req mm²/m |
Design | Dia (mm) | Spacing (mm) | As,prov mm²/m |
Utilisation | Status | |
Utilisation = As,req / As,prov. Status covers every check of the item: Mu,lim, steel required, minimum
and maximum steel, spacing (cl 26.3.3), bar diameter (D/8), shear (cl 40.2) and anchorage / development length.