Retaining Wall Designer IS 456:2000 · IS 1893

Reinforcement detailing - Cantilever Retaining Wall

Change the bar diameter or spacing of any item. Every change is checked against IS 456 at once and the section preview updates; "Design" shows the bars of the automatic design. Click a row for the detailed checks.

… Back to report CAD view
Steel (10.0 m of wall)-
Automatic design-
Difference-
Steel per m³-
User-defined items-
Items failing-
MarkMember / faceD (mm)As,req
mm²/m
DesignDia (mm)Spacing (mm)As,prov
mm²/m
UtilisationStatus

Utilisation = As,req / As,prov. Status covers every check of the item: Mu,lim, steel required, minimum and maximum steel, spacing (cl 26.3.3), bar diameter (D/8), shear (cl 40.2) and anchorage / development length.